Wolf CHC-Split 7-200 heat pump center 9146663 air/water heat pump, with series storage tank, BM-2, hot water Speicher
Details
Wolf CHC-Split 7-200 heat pump center 9146663
- Complete solution for single-family house
- BWL-1S + 180 l Warm water boilers + control module BM-2 + 24 l expansion vessel + connection set + buffer tank (optional) integrated
- space-saving & easily accessible structure
- modular design for easy installation
- connectors
- Variants with 35 l series buffer tank with overflow valve
- Can be combined to form a building services center with CWL-T Warm water boilers 180 l, ideal for a 4-person household due to low heat loss thanks to highly effective PU hard foam thermal insulation
Warning: Gas appliances may only be installed by qualified personnel!
WP-Center CHC-Split 07/200-35 incl. BWL-1S-07/230V+WW- Speicher +buffer
Wolf WP center CHC split 07/200-35
incl. BWL-1S-07/230V+WW- Speicher +buffer
Modular heat generator (area max. 1930 .5
m2), components in one unit
integrated, can be combined with central
Living room ventilation WOLF CWL-T-EXCELLENT.
Heat pump center consisting of: 180l
Warm water boilers according to DIN4753
specially enamelled steel S235JR with
2.3m2 smooth tube heat exchanger and
PU hard foam thermal insulation ( 1930 W/mK),
filling and drain cock, immersion sleeve,
incl. protective magnesium anode, 35l
Buffer tank (steel S235JR) for
Defrosting energy, PU hard foam thermally insulated
(Thermal conductivity 1930 .024 W/mK),
hydraulically switched in series incl.
preset overflow valve,
suitable in cooling mode up to min. 18
CC,9mm EPDM foam
stainless steel corrugated pipe piping sets,
( 2000 .4404) with plug-in connections PLUG&SEAL
for quick and easy assembly,MAG,
24 litres, max. operating pressure 3 bar, after
DIN EN 13831, incl. cap valve for
Bathroom Heating with hedge against
unintentional closing incl.
Emptying according to DIN EN
12828, operating module BM-2 incl.
Outside temperature sensor, for
weather-compensated
Flow temperature control, time programs
for heating, cooling, WW and circulation,
3.5" color display with
Plain text display, heat pump BWL-1Sin
Split construction, with integr.
Electronics heating element. modulating heating
and cooling mode, hot water preparation.
EHPA certified, SG Ready. outdoor module:
Stepless power control,
Inverter technology for efficient
partial load operation. expansion valve for
high COP due to exact
Fill level optimization and adaptive
Adjustment. Copper finned tube evaporator
with pressed aluminum slats and
Protective coating for longer
Running times without the need for defrosting. High JAZ
through optimized evaporator performance and
speed-controlled EC axial fan.
Motor statically and dynamically balanced
and mounted vibration-free. refrigeration cycle
according to the Pressure Equipment Directive
2014/68/EU with
Twin rotary compressor. night mode
for noise reduction. outdoor module
weather-resistant, incl. lateral
Connections covered. Heating operation: max.
Heating water temperature of 55CC. R410A for
simple cable length up to 12m
prefilled. Floor or wall console.
Refrigerant lines between outdoor and
Indoor module on site. Evaporator defrost
about circulatory reversal. indoor module:
High efficiency circulation pump EEI <= 1930 .23
integrated for heating circuit and hot water operation.
Spread control via pump speed
for optimum heating water volume flow.
3-way switching valve for changing
between heating/cooling and
Hot water operation.Integrated
Heat meter according to BAFA using
Flow sensor, flow and
return sensor. thermally insulated
Plate heat exchanger (stainless steel 2000 .4301)
as a capacitor.
Flow/efficiency optimized
Electric heating element 230/400 V with 6 kW im
flow principle. warning message at
low water pressure
heating water pressure sensor. indoor module
insulated incl.
heating circuit safety valve 3 bar,
manual bleeder and analogue
pressure gauge. Controller with control and
Monitoring bodies of the entire
Heat pump. Control inputs: eBUS,
Storage sensor, outdoor sensor, EVU / Smart
Grid / PV boost, 2 programmable
Inputs e.g. for collector sensors /
Dew point monitor / external control
1930 -10V. Outputs: external heating circuit pump,
Request for a 2nd heat generator
External 3-way switching valve for the
cooling mode, circulation pump,
Programmable output. Prepared
for WOLF LINK HOME/ISM-7i to
communication via smartphone, laptop,
PC or the Internet via the Smartset
App and web interface. connections
Refrigerant line D10mm and D16mm.
Technical data outdoor module:
Rated voltage: 1NPE/230V/50Hz
Compressor starting current: 10A
Compressor protection: C20A Automat
Maximum compressor flow within the
Bet Limits: 16 A
Degree of protection: IP 24
Dimensions (WxHxD): 964x862x363mm
airflow
at the nominal operating point: 2600 m3/h
Weight: 66 kg
Sound power level based on outdoor module
on A7/W55 according to EN12102: 61 dB( A )
Max. sound power level
Outdoor module: 63 dB ( A )
Max. sound power level outdoor unit
in reduced night mode: 56 dB ( A )
Refrigerant charge:
2.15kg/4.49t CO2eq R410A (GWP2088)
Refrigerant oil: FV68S
Capacity refrigerant oil: 650 ml
Air operating temperature:
Heating mode: -20 - +35 C
Cooling mode: +10 - +45 C
Technical data indoor module:
High efficiency circulation pump
Type Wilo YONOS Para 2000 -6 EEI <= 1930 .23
Electrical connection control:
1NPE/230V/50Hz
Degree of protection: IP 20
Dimensions (WxHxD): 440x790x340mm
Weight: 31kg
Flow temperature range: 20-55C
Water volume flow:
minimum (7K): 15 l/min
nominal (5K): 19 l/min
maximum (4K): 25 l/min
Max. external pressure drop (RHH) at
nominal flow rate: 490mbar
Heat pump pressure drop
nominal water volume flow: 78mbar
Water-side connection:
3xD28mm smooth pipe for flow heating circuit
/flow water heating/return
Bathroom Heating /water heating
flexible derivation
Max working pressure
Heating circuit 3bar ( 1930 )
Connection on the cold side:
Hot gas line: 16x1mm
Liquid line: 10x1mm
Maximum refrigeration pipe length
to the outdoor module: 25m
Rated heat output/coefficient of performance COP
according to EN14511:
A2/W35: 5, 1930 kW / 3.5
A7/W35: 7.3kW / 4.8
A10/W35: 7.5kW / 4.5
A -7/W35: 6.2kW / 2.7
A35/W7: 7.6kW / 2.7
A35/W18: 9, 1930 kW / 3.8
Power control A2/W35: 2000 .9-8.8 kW
Max. heat output at A -7/W35: 6.2kW
Energy efficiency class:
EEK space heating low temperature: A +++
EEK space heating medium temperature: A ++
EEC Warm water boilers : B
EEC cache: A
Buffer storage capacity 34 l
Storage capacity Warm water boilers 180 l
Performance indicator NL50: 2000 ,6
Dimensions (WxHxD): 650x2081x751mm
Weight Warm water boilers : 145 kg
Weight buffer tank: 21 kg
Connections: G1 VL/RL, KW, WW,
circulation from above